(4) Servo Type
Select the throttle servo type.  Digital servos offer the best response. 
Setting: Analog / DG:1520     Initial setting: Analog
WARNING 
 The servo type parameter within the CGY must match the type of servo 
you  are  using.    Incorrect  settings  may  damage  the  CGY  or  the  servo.    An 
incorrect setting may also result in the loss of control during flight.
< Model Menu (Helicopter) >
209
GOV Basic(Governor Basic Setting)
GOV Basic(Governor Basic Setting)
" screen.
(1) Governor: Governor active
Set the governor operation mode of CGY.  The initial setting is "ACT (ac-
tive)" where, as the designation implies, the governor is active. If you do 
not want to use governor, select "INH (Inhibit)".
Setting: ACT (Active) / INH (Inhibit)     Initial setting: ACT
(2) Gear Ratio:
Input  the  main  rotor  gear  ratio  by  pushing  the  "Gear  Ratio"  button  to 
select the desired working mode.
Setting ranges:  1.00 ~ 50.00 t     Initial value: 8.00  t
Notes:
• If  the  gear  ratio  is  not  properly  set, 
the  set  speed  and  actual  engine 
speed will be different.
• The gear ratio should be given in the 
helicopter  instruction  manual.    If  the 
helicopter  instruction  manual  does 
not  give  the  gear  ratio,  calculate  the 
gear ratio as follows: 
(3) Pole Num.: Pole number
This parameter is used when using a direct phase sensor attachment to 
a  brushless  motor  lead.  Input  the  motor  pole  count  as  specified  by  the 
brushless motor manufacturer.  When using any revolution sensor other 
than a direct phase sensor type, set the pole number to 2 p.
Note: For nitro use, set to 2 p. 
Note: The input signal range of the CGY is 0.0 v - 3.0 v. Exceeding this volt-
age range may cause damage to the CGY.
Setting ranges:  2 -24 P     Initial value: 2 P
(5) RPM set.: RPM setting
Setting the main rotor RPM.  This is calculated by engine revolution with 
the gear ratio of the main shaft.
When the rotation speed can be set with the governor mixing function of 
the transmitter, it is necessary to first match the display rpm value of 1-2-
3 of "RPM Set" with the display rpm value of the transmitter.
Setting ranges:  off / 700 ~ 4,000 rpm     Initial value: 1,000  rpm
*To set lower than 1,000  rpm, set "Low. Revo" of "GOV. EXPERT" menu to 700  rpm.
-
Note:  When  using  the  governor  function,  be 
sure to make each setting of "GOV.BASIC".
Note: After completing the linkage of the throt-
tle, be sure to set the "Servo limit point setting" 
first, and then set the other functions.
Engine
nion gear
N2
Gear ratio = N1/N2
  Carry values less than 1/1000 to the 
next whole number.
Rotor
main gear
N1