Range
When the variometer is greater
than this value, Vario melody is not
variable.
Setting range:
Offset value 〜 +50 m/s
Initial value:5.0 m/s
Offset
This is the changing point of climb and sink. When the variometer
is greater than this value, Vario Melody is climb type. When the
variometer is less than this value, Vario Melody is sink type.
Setting range:Range ↑ setting value 〜 Range ↓ setting value
Initial value:0.0 m/s
Delay
The output vario melody does not change during the
delay time. In other words, this is a minimum time of
Vario melody output.
Setting range:0.0 s,0.5 s,1.0 s,1.5 s
Initial value:0.0 s
*This parameter is effective to all variometers.
< Linkage Menu >
108
Tap the [Melody] button
Current variometer
When the variometer is less than
this value, Vario melody is not
variable.
Setting range:
-50 m/s 〜 Offset value
Initial value:-5.0 m/s
Deadband
When the variometer is less than
this value, Vario melody is not
output.
Setting range:0 m/s 〜 +50 m/s
Initial value:0.0 m/s
Fixed melody
Range↑
Variable melody
Deadband↑
Dead band
Offset
(Not sound)
Deadband↓
Variable melody
Range↓
Fixed melody
Actually Variometer
0.0 m/s
1.0 m/s
3.0 m/s
4.0 m/s
Output Vario Melody
0.0 m/s
1.0 m/s
3.0 m/s
4.0 m/s
Delay time
1.0 s
*These settings can be
set each sensors.
When the variometer is greater
than this value, Vario melody is not
output.
Setting range:-50 m/s 〜 0 m/s
Initial value:0.0 m/s
Climd side
Discontinuous
sounds
Sink side
Continuous
sounds
2.0 m/s
-1.0 m/s
-1.0 m/s
2.0 m/s