< Model Menu (Helicopter) >
207
Flight Tune(Aileron / Elevator Basic settings)
Flight Tune(Aileron / Elevator Basic settings)
Note:  To  effectively  operate  the  next  "ELE  Comp" 
(elevator  correction),  make  sure  to  set  "Pit  High", 
"Pit Zero", "Pit Low" on the "SWITCH BASIC" menu.
(7) ELE. Comp: Elevator pre compensation
A helicopter that has a head that rotates clockwise, will exhibit a tenden-
cy whereby the nose will be pulled towards the disk with positive blade 
pitch.   Conversely, the helicopter will push the nose away from the rotor 
disk during negative pitch inputs.  In an instance of a slower servo set-up 
or larger (heavier) rotor blades, a small amount of elevator pre compen-
sation may be needed to keep the nose of the helicopter flat at all times 
during  collective  pitch  changes.    In  most  cases  with  helicopter  high-
speed servos and standard 3D rotor blades, this function is not needed.   
If  you  do  notice  a  slight  tendency  for  the  nose  to  try  to  rise  or  fall  with 
collective input, increasing "ELE Comp" will reduce this behavior.
Setting ranges:  0 ~ 100%     Initial value: 0%
(8) HP. Auth.: High pitch authority
When a rotor blades angle of attack is increased, the rotor blade becomes 
less reactive, in turn the helicopter might not feel as reactive at high pitch 
angles.    If  you  want  to  increase  the  reaction  of  the  cyclic  during  loaded 
and high pitch maneuvers, "HP. Auth" will increase control authority and 
can be used to make the helicopter feel more linear under loading.  Some 
helicopters  with  direct  link  CCPM  may  use  this  to  increase  stability  at 
high collective pitch flying as well.  If a helicopter feels good for normal 
flying, but not the same during loaded situations, "HP. Auth" can be used 
to make it feel more linear.  If "HP. Auth" is set very high, the helicopter 
will feel more aggressive at high pitch than around neutral.
Setting ranges:  0 ~ 100%  Initial value: HP. Auth = 0%