Operating & Maintaining the Connex500/350 3D Printer
External UV meter The following steps apply when using a stand-alone UV meter. They do
6–54
not apply when using the Stratasys UV sensor connected to the printer.
1. When the following screen appears, open the printer and place the UV 
sensor at the rear edge of the tray, in the center.
Figure 6-80: Sensor placement screen
Figure 6-81: Correct UV-sensor placement
2. Lead the cable out of the printer so that you can close the printer, and 
make sure that the cable will not interfere with the moving print block.
3. Close the printer, while checking that the sensor does not move out of 
position.
4. Set the UV meter to measure mJ/cm2.
5. Set the range on the meter to 2,000.
6. Connect the cable from the sensor to the UV meter. 
7. Turn on the UV meter, and wait until "0 0 0.0" appears on the display.
8. In the wizard screen, confirm that the sensor is positioned correctly, 
and click 
.
Next
Continue with "UV measurement" on page 55.