Cleaning the
Roller Waste
Collector and
Inspecting the
Roller Scraper
DOC-13025 Rev. A
The roller waste collector removes waste material scraped from the roller.
Suction removes this waste to the printer's waste container.
This assembly should be cleaned weekly to prevent a blockage in the tubes
leading to the waste container, so that waste material does not overflow
into the printer.
To clean the roller waste collector:
1. Prepare—
•
M2.5 and M2 Allen
•
disposable cleaning gloves
•
isopropanol (IPA—isopropyl alcohol) or ethanol (ethyl alcohol)
•
cleaning cloth
•
cotton swabs (Q‐tips or similar)
2. Put on the gloves.
3. Remove the right UV‐lamp assembly:
a. Disconnect the UV power cable and the fan power cable.
Figure 6-34: Disconnecting the right UV assembly
b. Remove the screw attaching the right UV lamp to the print block,
and then pull and lift up the UV lamp.
Connex500/350 User Guide
®
keys
Fan power
connector
UV Power
connector
Screw
6–29