Operating & Maintaining the Connex500/350 3D Printer
6–24
9. Clean the orifice plates, with a back‐and‐forth motion (see figure 6‐25). 
Use the mirror to make sure that you have removed all of the residue 
material.
Figure 6-25: Cleaning the heads
10. Clean the entire roller surface, by rotating it as you clean.
Use this opportunity to clean the glass lens on the UV lamps.
11. When you have finished cleaning, select the confirmation check box in 
the wizard screen (see figure 6‐24) and click 
12. Remove the cleaning materials from the printer and close the cover. 
13. Select the confirmation check boxes in the wizard screen and click 
.
Next
The head‐purge cycle begins. When this is complete, the final wizard 
screen appears.
Figure 6-26: Head-cleaning wizard—final screen
14. Click 
 to close the wizard.