To check the effectiveness of the roller scraper:
1. Put on the cleaning gloves.
2. Wet a cloth with isopropanol.
3. Use the cloth to wet the bottom of the roller.
4. Turn the roller slowly with your hand. As the blade scrapes the roller, 
make sure the isopropanol is spread evenly over the entire length of 
the blade.
5. Inspect the roller. If it is not dry, replace the blade. (See "Replacing the 
Roller Scraper" on page 32.)
6. Before returning the roller waste collector to the print block, make sure 
that the pins are clean. 
Figure 6-38: Roller waste collector pins
To re-assemble the components:
1. Return the roller waste collector to the print block and screw on the 
covering (see figure 6‐36 on page 30).
2. Loosen the screws securing the suction tube.
Figure 6-39: Suction tube correctly positioned
3. Lower it so that the hole in the panel behind the suction tube is visible, 
and tighten the screws to secure the tube. 
4. Attach the right‐UV‐lamp assembly to the print block and reconnect 
the UV power and fan cables.
Securing screws