Function Description Installation Menu - Honeywell VERSAFLOW SONIC 1000/TWS 9000 Handbook

Ultrasonic clamp-on flowmeter for liquids
Table of Contents

Advertisement

START-UP
5

5.3 Function description installation menu

Menu
Display
No.
Power
I: power fail
up
I: installation
required
I: press key ">"
X X X X
Installation
Installation
Installation
Installation
X1
X1
language
X1 X1
X2 X2
X2
X2
GDC IR
GDC IR
GDC IR
GDC IR
interface
interface
interface
interface
X3
X3
units
units
X3 X3
units
units
X3.1
size
X3.2
volume flow
X3.3
free unit
X3.4
3
[m
/s]*factor
X3.5
velocity
X3.6
density
X3.7
temperature
X4
X4
X4 X4
pipe
pipe
pipe
pipe
configuration
configuration
configuration
configuration
X4.1
number of
pipes
X4.2
number of
paths
X5
X5 X5
X5
pipe data
pipe data
pipe data
pipe data
X5.2
diameter
X5.3
pipe material
X5.4
VoS pipe
material
X5.5
wall thickness
X5.6
liner material
X5.7
VoS liner
material
X5.8
liner thickness
X5.9
fluid
X5.10
VoS fluid
X5.11
density
96
Function description
Standard indication that the
converter has been powered off
Indication that the device has not
been installed before
To access installation menu
Start installation device
Select preferred language
Connection IR interface
Selectable units
Unit for dimension
Unit for volume flow
Sequences to set texts and
factors
Conversion factor
Unit for flow speed and velocity of
sound (VoS)
Unit for density
Unit for temperature
number of pipes (1-2) and number of paths (1-2), in case "2 paths" is selected, the
measurement results will be averaged.
Selection 1 or 2 pipe(s)
Selection 1 or 2 path(s)
Input menu
Size for outer diameter of pipe
Select pipe material from list
Input menu
Input menu
Input menu
Input menu
Input menu
Input menu
Input menu
Input menu
www.honeywellprocess.com
VERSAFLOW SONIC 1000/TWS 9000
Selection list, additional info
Keep key ">" pressed until in display appears: "release
key now"
activate (the IR interface (adapter) and interrupt the
optical keys)
mm; inch
L/s; L/min; L/h; m³/s; m³/min; m³/h; m³/d; ft³/s;
ft³/min; ft³/h; gal/s; gal/min; gal/h; gal/d; IG/s; IG/min;
IG/h; IG/d; bbl/h; bbl/d; free unit
For text to be specified refer to
140
specification of the conversion factor, based on m³/s.
m/s; ft/s
kg/L; kg/m³; lb/ft³ lb/gal; free unit
°C; °F; K
1 pipe, 2 pipes
1 path; 2 paths
pipe 1 data
min-max: 20...4300 mm / 0.787...169.3 inch
carbon steel; stainless steel; cast iron; aluminum;
concrete; GRF/RFP; asbestos cement; PP/PVC;
acrylics; polyamide; other
min-max: 1000.0...4500.0 m/s / 3280.8... 14764 ft/s
min-max: 1.000...200.0 mm / 0.039...7.874 inch
cement, epoxy, PP, LDPE, HDPE, PTFE, rubber, other,
none
min-max: 1000.0...4500.0 m/s / 3280.8...14764 ft/s
min-max: 0.100 - 20.00 mm / 0.004 - 0.787 inch
water; alkanes; alcohols; oil; acids; CxHx refined; CxHx
light; refrigerant; solvents; caustic soda; other
min-max: 500...2500 m/s / 1640.4...8202.1 ft/s
min-max: 0.1000...5.0000 kg/l / 6.2428 lb / ft³ to 312.14
lb/ft³
Set free units
on page
34-VF-25-07 iss.2 GLO Nov 11 US

Advertisement

Table of Contents
loading

Table of Contents