4.9 Description of the inputs and outputs

4.9.1 Control input

INFORMATION!
Depending on the version, the control inputs must be connected passively or actively or
according to NAMUR EN 60947-5-6! Which I/O version and inputs/outputs are installed in your
signal converter are indicated on the sticker in the cover of the terminal compartment.
• All control inputs are electrically isolated from each other and from all other circuits.
• All operating data and functions can be adjusted.
• Passive mode: external power supply required:
≤ 32 VDC
U
ext
• Active mode: use of the internal power supply:
U
= 24 VDC
nom
• NAMUR mode: in accordance with EN 60947-5-6
(Active control input to EN 60947-5-6 (NAMUR): signal converter monitors cable breaks and
short circuits acc. to EN 60947-5-6. Errors indicated on LC display. Error messages possible
via status output).
• For information on the adjustable operating states refer to
DANGER!
For devices used in hazardous areas, additional safety notes apply; please refer to the Ex
documentation.
34-VF-25-07 iss.2 GLO Nov 11 US
ELECTRICAL CONNECTIONS
www.process.honeywell.com
Function tables
on page 120.