3.7.9 Pipe diameters and sensor rail(s) construction

INFORMATION!
Check the ordered rail(s) with the preferred measuring mode
Figure 3-10: Measuring modes
1 Z-mode
2 V-mode
3 W-mode
4 X-mode
5 V-mode; large set rails
Overview version and measuring modes
Rail version
Rail version
Rail version
Rail version
Small
Medium
Large
Table 3-1: Version and preferred measuring mode

3.7.10 Pipe and media parameters

INFORMATION!
Detailed databases of most pipe and media parameters are available. Contact Product Support
or check the manufacturer website.
34-VF-25-07 iss.2 GLO Nov 11 US
Diameter range
Diameter range
Diameter range
Diameter range
DN15...100 / 0.5...4"
DN50...400 / 2...16"
DN200...2000 / 8...80"
DN200...4000 / 8...160"
www.process.honeywell.com
INSTALLATION
Preferred measuring
Preferred measuring
Preferred measuring
Preferred measuring
modes
modes
modes
modes
< DN25: W-mode (4
traverses)
≥ DN25: V-mode (2
traverses)
V-mode (2 traverses)
V-mode (2 traverses)
Z-mode (1 traverse)
3
Possible measuring
Possible measuring
Possible measuring
Possible measuring
modes
modes
modes
modes
Small: V-mode