Honeywell VERSAFLOW SONIC 1000/TWS 9000 Handbook page 206

Ultrasonic clamp-on flowmeter for liquids
Table of Contents

Advertisement

DESCRIPTION OF HART INTERFACE
9
Detailed Setup
Detailed Setup
Detailed Setup
Detailed Setup
transducer sets
I/O
206
Ta serial no. / calibration number / Tb serial no. / calibration number /
Tc serial no. / calibration number
hardware
terminals A / terminals B / terminals C / terminals D
current out A
range 0% / range 100% / extended range min /
extended range max / error current /
error condition / measurement / range min / range max / polarity /
limitation min / limitation max / LFC threshold / LFC hysteresis /
time constant / special function / threshold / hysteresis / information /
Simulation current output A
frequency out A
pulse shape / pulse width / 100% pulse rate / measurement / range min /
range max / polarity / limitation min / limitation max / LFC threshold /
LFC hysteresis / time constant / invert signal / information /
Simulation frequency output A
pulse output A
pulse shape / pulse width / max. pulse rate / measurement /
value p. pulse / polarity / LFC threshold / LFC hysteresis /
time constant / invert signal / information /
Simulation pulse output A
status output A
mode / output B / invert signal / information / Simulation status output A
limit switch A
measurement / threshold / hysteresis / polarity / time constant /
invert signal / information / Simulation limit switch A
control input A
mode / invert signal / information /
Simulation control input A
current in A
range 0% / range 100% / extended range min / extended range max /
measurement / range min / range max / time constant / information
current out B
range 0% / range 100% / extended range min/ extended range max /
error current / error condition / measurement / range min / range max /
polarity / limitation min / limitation max / LFC threshold /
LFC hysteresis / time constant / special function / threshold /
hysteresis / information / Simulation current output B
frequency out B
pulse shape / pulse width / 100% pulse rate / measurement / range min /
range max / polarity / limitation min / limitation max / LFC threshold /
LFC hysteresis / time constant / invert signal / information /
Simulation frequency output B
pulse output B
pulse shape / pulse width / max. pulse rate / measurement /
value p. pulse / polarity / LFC threshold / LFC hysteresis /
time constant / invert signal / special function / information /
Simulation pulse output B
status output B
mode / output A / invert signal / SW.REV.MS / information /
Simulation status output B
limit switch B
measurement / LFC threshold / LFC hysteresis / polarity /
time constant / invert signal / SW.REV.MS / information /
Simulation limit switch B
control input B
mode / invert signal / SW.REV.MS / information /
Simulation control input B
current in B
range 0% / range 100% / extended range min / extended range max /
measurement / range min / range max / time constant / information
current out C
range 0% / range 100% / extended range min/ extended range max /
error current / error condition / measurement / range min / range max /
polarity / limitation min / limitation max / LFC threshold /
LFC hysteresis / time constant / special function / threshold /
hysteresis / information / Simulation current output C
status output C
mode / output A / invert signal / SW.REV.MS /
Simulation status output C
limit switch C
measurement / threshold / hysteresis / polarity / time constant /
invert signal / SW.REV.MS / Simulation limit switch C
www.process.honeywell.com
VERSAFLOW SONIC 1000/TWS 9000
34-VF-25-07 iss.2 GLO Nov 11 US