3.8.11 Installing the DOWN sensor rail in Z-mode

Figure 3-22: Finding the location for the DOWN sensor rail
1 Measure the distance between the transducer and the end of the UP sensor rail.
2 Advised distance as shown in menu X7.4
3 Determine and mark the location of the transducer of the DOWN sensor rail: 3 3 3 3 = 1 1 1 1 - 2 2 2 2
• Install the DOWN sensor rail in such a way that the transducer is at the marked location
• Always use coupling grease/pads, refer to
INFORMATION!
Continue with the instructions as described in the section refer to General instructions for
programming on page 95
INFORMATION!
It can be necessary to install the DOWN sensor rail as shown below.
Figure 3-23: Transducers almost opposite, distance small 1
The installation of the sensor rails are (more or less) facing straight and metal straps are
mounted close beside each other.
• Always use coupling grease/pads, refer to
INFORMATION!
Continue with the instructions as described in the section refer to General instructions for
programming on page 95
34-VF-25-07 iss.2 GLO Nov 11 US
General mechanical installation
.
General mechanical installation
.