Cable insert and usage connector tool
Figure 4-10: Construction of field version
1 Signal converter
2 Open connection terminal
3 Tool for releasing connectors
4 How to use the release tool
5 Marking on the cables
6 Insert cable(s) into connection terminal
Corresponding cable connections
Connections
converter
1.1
1.2
2.1
2.2
3.1
3.2
34-VF-25-07 iss.2 GLO Nov 11 US
Marking / color cable
U or 1.1 / Blue
D or 1.2 / Green
U or 2.1 / Blue
D or 2.2 / Green
not connected
not connected
www.process.honeywell.com
ELECTRICAL CONNECTIONS
Configuration
1 path / 1 pipe
1 path / 1 pipe
2 path / 2 pipes
2 path / 2 pipes
-
-
4
Transducer
Upstream
Downstream
Upstream
Downstream
-
-