Installing The Down Sensor Rail In V-Mode - Honeywell VERSAFLOW SONIC 1000/TWS 9000 Handbook

Ultrasonic clamp-on flowmeter for liquids
Table of Contents

Advertisement

VERSAFLOW SONIC 1000/TWS 9000

3.8.7 Installing the DOWN sensor rail in V-mode

The V-mode installation is based on a reflected path and can be used depending on the medium
and pipe conditions. It can be applied for the large sensor rails up to DN2000/80". The installation
of a set of large sensor rails in V-mode is easier than in a Z-mode because both sensor rails are
installed over the same centerline on the same side of the pipe (both rails are installed directly
in line with each other). The minimum transducer distance possible is 210 mm which means its
suitable from DN300/12".
Figure 3-16: Mounting large version in V-mode
1 Optional fixing units
2 Reference marking
3 Optional cable (splitter) box
4 Advised Distance; menu X7.4 (calculated distance min. 210 mm/8.3"
• Always use coupling grease/pads, refer to
INFORMATION!
Continue with the instructions as described in the section refer to General instructions for
programming on page 95
34-VF-25-07 iss.2 GLO Nov 11 US
General mechanical installation
.
www.process.honeywell.com
INSTALLATION
on page 32.
3