Honeywell VERSAFLOW SONIC 1000/TWS 9000 Handbook page 97

Ultrasonic clamp-on flowmeter for liquids
Table of Contents

Advertisement

VERSAFLOW SONIC 1000/TWS 9000
X5.12
glycol % vol.
X5.13
dynamic
viscosity
X5.14
pipe
temperature
X6
X6 X6
X6
pipe data 2
pipe data 2
pipe data 2
pipe data 2
X6._
Additionally X6.1 copy pipe data 1 is available. The other menu X6 items are exactly the same as the menu
items X5 and will only be available, when number of pipe selection is 2 pipes in menu item X4.
X7
X7
X7 X7
Install
Install
Install
Install
transducer 1
transducer 1
transducer 1
transducer 1
X7.1
transducer set
X7.2.1
calibration
number
X7.2.2
number of
traverses
X7.2.3
mount
transducers at
X7.2.4
act.flow prelim. Preliminary volume flow
X7.2.5
check signal
X7.2.6
actual distance
X7.2.7
optimize
distance
X7.2.8
actual flow
preliminary
X7.2.9
path ready?
X7.2.11
end installation Exit installation mode
X8
X8
X8 X8
Install
Install
Install
Install
transducer 2
transducer 2
transducer 2
transducer 2
X9
X9
Install
Install
X9 X9
Install
Install
transducer
transducer
transducer
transducer
sets
sets
sets
sets
X9.1/3/5
Tx serial
number
X9.2/4/6
Tx calibration
number
x stands for: a;
b; c
34-VF-25-07 iss.2 GLO Nov 11 US
Input menu
Input menu
Input application temperature
Input menu
Enters installation procedure for
transducer 1
Short code for transducer set,
mentioned on sensor
Read calibration number
Description of installation mode
Advised transducer distance
Actual signal quality
Input menu for transducer
distances
Enter optimize loop
Preliminary volume flow
Select if installation is completed
is identical the menu items of X7
Factory serial number of sensor
Set calibration number of sensor
according to type sticker
www.process.honeywell.com
min-max: 0...100%
min-max: 0.100 ...9999 cP (N s/m²)
min-max: -40...+200°C
pipe 2 data
Ta, Tb, Tc, none
123456789
1, 2 or 4 traverses
+ xx.xx mm
± xx.xx m³/h
0...100%
Confirm or adjust
min-max: -10.00...+9999 mm / -0.394...+393.7 inch
yes/no
± xx.xx m³/h
yes/no
yes/no
Ready?; or install next transducer?
Ayy; 5 free units
9 free units
START-UP
5
97

Advertisement

Table of Contents
loading

Table of Contents