Process Variables Root Menu; Diagnostic Root Menu - Honeywell VERSAFLOW SONIC 1000/TWS 9000 Handbook

Ultrasonic clamp-on flowmeter for liquids
Table of Contents

Advertisement

DESCRIPTION OF HART INTERFACE
9

9.9.4 Process Variables Root Menu

Process Variables
Process Variables
Process Variables
Process Variables
Process Values
Totalizer
Diagnosis Values
In-/Outputs, HART
Dynamic Variables
Table 9-8: Process Variables Root Menu

9.9.5 Diagnostic Root Menu

Device Status
Device Status
Device Status
Device Status
Condensed Status (NE 107)
HART Standard Status
Write Protect
Additional
Simulation
Simulation
Simulation
Simulation
volume flow
velocity of sound
simulation IO
Actual Values
Actual Values
Actual Values
Actual Values
act. volume flow / act. volume flow 2 / act. mass flow /
act. flow speed / act. Reynolds number 1 / act. Reynolds no. 2 /
act. vel. of sound path 1 / act. vel. of sound path 2 / act. gain path 1 / act. gain path 2 /
act. SNR path 1 / act. SNR path 2 / act. signal quality path 1 / act. signal quality path 2 /
opt. transd. distance path 1 / opt. transd. distance path 2 / operating hours
Information
Information
Information
Information
C number / Sensor CPU / Sensor DSP / Sensor Driver / SW.REV. MS / SW.REV. UIS / Electronic Revision
Test/Reset
Test/Reset
Test/Reset
Test/Reset
Reset errors / Warmstart / Device reset / Reset Configuration Changed Flag
Table 9-9: Diagnostic Root Menu
202
Volume Flow / Velocity of sound / Mass Flow / Flow speed / Heat Flow / Cold Flow /
Volume Flow 2 / Volume Flow 12 / Temperature A / Temperature B / Operating hours
Volume Totalizer 1 / Mass Totalizer 1 / Energy Totalizer 1 / Volume 2 Totalizer 1 /
Volume Totalizer 2 / Mass Totalizer 2 / Volume 2 Totalizer 2 / Volume 12 Totalizer 2 /
Volume Totalizer 3 / Mass Totalizer 3 / Energy Totalizer 3 / Volume 12 Totalizer 3
Gain / SNR / Diag. Gain 1 / Diag. SNR 1 / Diag. Gain 2 / Diag. SNR 2
Primary / Secondary / Tertiary / Quaternary / Time and simulation
F Configuration / F Electronics / C Configuration / S Process / S Configuration /
S Electronics / M Configuration / M Electronics / M Sensor / Proc: Signal Lost /
Proc: Empty Pipe / Electr: IO Connection / Proc: Current Input / Electr: Power Failure /
Installation required / Config: Totaliser / Proc: Signal Unreliable /
Electr: Operation Info. / Config: No Meas.Value / Show single events
Simulation current output A / Simulation frequency output A /
Simulation pulse output A / Simulation status output A / Simulation limit switch A /
Simulation control input A /
Simulation current output B / Simulation frequency output B /
Simulation pulse output B / Simulation status output B /
Simulation limit switch B / Simulation control input B /
Simulation current output C / Simulation status output C /
Simulation limit switch C /
Simulation frequency output D / Simulation pulse output D /
Simulation status output D / Simulation limit switch D
www.process.honeywell.com
VERSAFLOW SONIC 1000/TWS 9000
34-VF-25-07 iss.2 GLO Nov 11 US