Honeywell VERSAFLOW SONIC 1000/TWS 9000 Handbook page 173

Ultrasonic clamp-on flowmeter for liquids
Table of Contents

Advertisement

VERSAFLOW SONIC 1000/TWS 9000
Display and user interface
Display and user interface
Display and user interface
Display and user interface
Graphic display
Operator elements
Remote control
Display functions
Display functions
Display functions
Display functions
Operating menu
Language of display texts
Measurement functions
Diagnostic functions
Measuring accuracy
Reference conditions
Maximum measuring error
Repeatability
34-VF-25-07 iss.2 GLO Nov 11 US
LCD; backlit white
Size: 128 x 64 pixels; corresponds to 59 x 31 mm = 2.32" x 1.22"
Display turnable in 90° steps
Four optical and mechanical pushbuttons for operator control of the
signal converter without opening the housing
Option: infrared interface (GDC)
®
PACTware
including Device Type Manager (DTM)
®
HART
hand-held communicator (Emerson), AMS (Emerson), PDM
(Siemens).
All DTM's and drivers are available at the internet homepage of the
manufacturer
Programming of parameters at 2 measured value pages, 1 status page, 1
graphic page (measured values and descriptions adjustable as required).
English, German, French, Russian.
Units: Metric, British and US units selectable from a list for
Units:
Units:
Units:
volume/mass flow and counting, velocity, temperature.
Measured values: Volume flow, mass flow, flow speed, velocity of sound,
Measured values:
Measured values:
Measured values:
gain, signal to noise ratio, flow direction, diagnostics.
Standards: VDI/NAMUR NE 107
Standards:
Standards:
Standards:
Status messages:
Status messages: the output of status messages via display, current
Status messages:
Status messages:
and/or status output, HART® or via other bus interfaces.
Sensor diagnostics: per acoustic path velocity of sound, flow speed, gain,
Sensor diagnostics:
Sensor diagnostics:
Sensor diagnostics:
signal to noise ratio.
Process diagnostics: empty pipe, signal integrity, cabling, flow
Process diagnostics:
Process diagnostics:
Process diagnostics:
conditions.
Signal converter diagnostics: data bus monitoring, I/O connections,
Signal converter diagnostics:
Signal converter diagnostics:
Signal converter diagnostics:
electronics temperature, parameter and data integrity.
Medium: water
Temperature: 20°C / 68°F
Pressure: 1 bar/14.5 psi
Straight inlet section: 10 DN
Straight outlet section: 5 DN
≥ DN50 / 2 inch
< ± 1% of the actual measured flow rate; for 0.5...20 m/s / 1.64...65.6 ft/s
< ± 5 mm/s / 0.2 inch/s for 0.1...0.5 m/s / 0.33...1.64 ft/s
< DN50 / 2 inch
< ± 3% of the actual measured flow rate; for 0.5...20 m/s / 1.64...65.6 ft/s
< ± 15 mm/s / 0.6 inch/s for 0.1...0.5 m/s / 0.33...1.64 ft/s.
± 0.2%
www.process.honeywell.com
TECHNICAL DATA
8
173