INSTALLATION
3
3.7.7 Position of pump
Figure 3-8: Position of pump
INFORMATION!
Recommended position to install a flowmeter is downstream a pump (on a position where the
flow disturbances of the pump are resolved)
A clamp-on flowmeter can be installed in the suction line of a pump if there is no cavitation in the
pipeline system.
3.7.8 Position of control valve
Figure 3-9: Position of control valve
INFORMATION!
Recommended position to install a flowmeter is upstream a control valve.
A clamp-on flowmeter can be installed downstream of the control valve if there is no cavitation
in the pipeline system (e.g. flow profile disturbances are resolved).
30
www.process.honeywell.com
VERSAFLOW SONIC 1000/TWS 9000
34-VF-25-07 iss.2 GLO Nov 11 US