Installing The 2Sff Nvme Drive Cage - HPE ProLiant DL325 Gen10 User Manual

Table of Contents

Advertisement

18. Power up the server.
19. If removed, install the bezel.
The installation is complete.

Installing the 2SFF NVMe drive cage

Prerequisites
Before you perform this procedure, make sure that you have a T-10 Torx screwdriver available.
Procedure
1.
If installed, remove the bezel.
2.
Power down the server.
3.
Remove all power:
a. Disconnect each power cord from the power source.
b. Disconnect each power cord from the server.
4.
Disconnect all peripheral cables from the server.
5.
Do one of the following:
Extend the server from the rack.
Remove the server from the rack.
6.
Remove the access panel.
7.
Remove the media bay blank.
8.
Install the 2SFF NVMe drive cage assembly.
9.
Connect the signal and power cables for the 2SFF NVMe drive cage.
60