DME1 to DME8: Select a DME channel.
P-Bus: Select the P-Bus region.
GPI: Select the GPI region.
RTR: Select the router region.
DEV1 to DEV12: Select the Device 1 to
Device 12 regions respectively.
MCRO: Select the macro region.
c Function selection buttons
UNDO: After recalling a register, press this
button to return to the state before
recalling the register.
STORE STATS (store status): This lights
amber when data is stored in a register.
After saving data to a register, hold
down this button and press the
[UNDO] button to return the register to
the state before the data was saved.
STORE: Press this button to switch to the
mode for saving a snapshot, effect,
shotbox or macro in a register.
RCALL (recall): Press this button to
switch to the mode for recalling a
snapshot, effect, shotbox or macro
from a register.
[STORE] button or [RCALL] button
flashes amber when one or more of the
regions assigned to the Region selection
buttons are not selected by the Region
Select menu.
d Numeric keypad
In addition to the buttons for numeric input,
this includes buttons for adding attributes to
snapshots.
0 to 9: Used to input numeric digits.
. (period): Enters the decimal point.
When the [TRANS RATE] button is lit,
enters "00." When the [EFF] button,
[SNAPSHOT] button or [SHOTBOX]
button is lit, this is used to find an
empty register.
+/–/ EFF DISS (effect dissolve): Invert the
sign, negative or positive.
When the [SNAPSHOT] button is lit,
applies the effect dissolve attribute to a
snapshot.
CLR/AUTO TRANS (clear/auto
transition): Clear an input value,
returning to the previous state.
When the [SNAPSHOT] button is lit,
applies the auto transition attribute to a
snapshot.
TRIM/GPI ENBL (enable): After
entering a difference value to be added
to an existing setting, press this button
to confirm the change.
ENTER: Confirm an entered value.
e Display
This shows the selected region name and
entered numeric values.
Names and Functions of Parts of the Control Panel
67