4.11 ERROR CODES

In the event of an error, the dispenser will end the sale and display a message on the side of the
dispenser where the error occurred. To clear an error message put the nozzle back in the boot and
remove the nozzle again. Refer to Diagnostic Code 02 for more information.
NOTE: Repair the problem before clearing the message. If an error message continues to be displayed,
contact your Authorized Bennett Service Provider
Error
Display
Code
Error Text
00
NO ERROR
02
RAM DATA
03
ATC COLD
04
ATC HOT
05
REV FLO
06
REVFLO A
07
REVFLO B
08
REVFLO C
09
REVFLO D
13
PULSERAS
14
PULSERAN
15
PULSERAR
16
PULSERAD
17
PULSERAG
18
619 PR A
23
PULSERBS
24
PULSERBN
25
PULSERBR
26
PULSERBD
27
PULSERBG
28
619 PR B
33
PULSERCS
34
PULSERCN
35
PULSERCR
36
PULSERCD
37
PULSERCG
3000 Series Operation Manual
No Error
Ram Error
The automatic temperature compensation probe reads less than -30
The automatic temperature compensation probe reads less than +40
Reverse Pulser – Inactive Pulser Turning Forward or Backwards
Detected Pulser A Rotating Backwards
Detected Pulser B Rotating Backwards
Detected Pulser C Rotating Backwards
Detected Pulser D Rotating Backwards
Pulser A Error Same State Transition Limit Exceeded
Pulser A Next State Transition Limit Exceeded
Pulser A Reverse Flow
Pulser A Lead Channel Failed
Pulser A Lag Channel Failed
Grade A was Active when the Lower CPU Stopped Responding
Pulser B Same State Transition Limit Exceeded
Pulser B Next State Transition Limit Exceeded
Pulser B Reverse Flow
Pulser B Lead Channel Failed
Pulser B Lag Channel Failed
Grade B was Active when the Lower CPU Stopped Responding
Pulser C Same State Transition Limit Exceeded
Pulser C Next State Transition Limit Exceeded
Pulser C Reverse Flow
Pulser C Lead Channel Failed
Pulser C Lag Channel Failed