3.24 MENU CODE 20: MASKED VOLUME
Skip this section if in the United States. Masked Volume is only used in countries that require
compliance with OIML standards. Masked Volume defines when fuel flow begins to register on the
display.
The factory default for is set to 0.010 gallons, or 0.10 liters per U.S. Weights and Measures.
• OIML requires a setting of 0.05 liters for a 40LPM dispensers and .11 liters for an 80LPM
dispenser.
• The masked volume amount can be any value between 00 and 99 (0.099 gallons or 0.99 liters).
See the Masked Volume Examples table below.
To program:
• The calibration switch on the 719 must be in the unsealed position to access menu code 20.
• Passcode required, see Section
Keypad
Retail Display
Action
Results
20, Mode
F L O S t A r t
P U L S E 1 0
Type value
F L O S t A r t
between 00
P U L S E - 0 2
and 99
F L O S t A r t
Enter
P U L S E 0 2
C 0 d E
Cancel
Masked Volume Examples
Unit of Measure
Gallons
Liters
Gallons
Liters
Gallons
Liters
3000 Series Operation Manual
3.4 Menu Code 3: Manager
Volume Only
Display Results
F L O 6 0 1 0
F L O 6 0 - 0 2
F L O 6 0 0 2
C O d E 0 0
0 0
FStart Volume
Start of Sale Recognition
2
2
10
10
45
45
Back to TOC
Access.
Lower PPV
Display Results
C O d E
C O d E
C O d E
S i d E -
0.002 Gallons
0.02 Liters
0.010 Gallons
0.10 Liters
0.045 Gallons
0.45 Liters
Setup and Programming
Description
Default is 10.
See bullets above and table
below for setting values.
Overwrite any typo
anytime.
Enter to save.
Exit Menu Code
35

Advertisement

Table of Contents
loading

Table of Contents