3.15 MENU CODE 9: NO FLOW TIMEOUT
NOTE: If programming a two-sided dispenser, changing one side will automatically change the second
side to the same value as the first.
The dispenser can be programmed to shut OFF if no flow of fuel occurs within a specific amount of time
specified. No flow timeout ends the sale in the time frame specified.
To program the No Flow Time Out feature, follow this procedure:
• Passcode required, see Section
Keypad
Retail Display
Action
Results
9, Mode
N O F L O
Chose a time:
N O F L O
0-9, Enter
N O F L O
NOTE: If an error is made, press the 0 key until all three digits are zeros and enter a new number or push
the number keys until the correct number of seconds appears in the volume display.
IMPORTANT: The dispenser will not operate if 0 seconds are set. To disable set to default.
3000 Series Operation Manual
3.4 Menu Code 3: Manager
Volume Only
Display Results
N F L O - - -
- - -
N F L O - 0 0 1
0 0 1
N F L 0 - - - -
- - -
Back to TOC
Access.
Lower PPV
Display Results
Default. No Flow Timeout
C O d E
One second for example.
Type any number to
C O d E
overwrite previous input
Return to default
C O d E
Setup and Programming
Description
is disabled.
and then Enter
25