Diagnostic Code 5: Pump Handle; Est; Ounter - Bennett 3000 Series Operation Manual

Hide thumbs Also See for 3000 Series:
Table of Contents

Advertisement

4.6 DIAGNOSTIC CODE 5: PUMP HANDLE TEST
Tests the integrity of the pump handle switches. The nozzle handle rests on a switch that turns ON the
pump for the dispenser.
1. Press 0, Mode to enter diagnostics Mode 00.
2. Press 5, Enter. Line 1 of the Main Display will show "HAndLE" or "HNdl".
3. When a handle switch is lifted, the display will show "A, B, C, or D" which should correspond
to the handle lifted.
4. Press Cancel to exit this test.
4.7 DIAGNOSTIC CODE 6: DIAGNOSTIC COUNTER
View the power failure counters, cold start counters, EEPROM checksum fails, software restarts, and
EEPROM update starts. NOTE: Press the Enter button to cycle through the diagnostic counters.
Keypad
Action
0, Mode
6, Enter
↑, ↓, +/-
Enter
Enter
Enter
Enter
Cancel
3000 Series Operation Manual
Retail Display
Volume Only
Results
Display Results
G A L L O N
0
P f A I L S
0
C S t A r t
0
E E C H E C
0
r S t A r t
0
E S t A r t
0
C O d E
S i d E - - 1
0 0
Back to TOC
Description
Enter Diagnostics
G A L 0
POWER FAILURES and the
number of power failures
P F 0
since the system was
reset (cold start).
This key code zeros out
the PF count, if needed.
Advances to
COLD START (the number
C S 0
of cold starts is shown)
Advances to
EEPROM CHECKSUM
FAILS (the number of
E E 0
EEPROM Checksum fails is
shown)
Advances to
SOFTWARE RESTARTS
FAILS (the number of
r S 0
software restarts is
shown)
Advances to
EEPROM UPDATE STARTS
(amount of resets that
E 5 0
occurred during an
EEPROM update)
Exit Menu Code
Diagnostics
63

Advertisement

Table of Contents
loading