Page 1
Keep this manual and tell all service personnel to read this manual. If you do not follow the instructions, you can cause bodily injury, death, or damage to the equipment. Bennett 1218 E. Pontaluna Road, Spring Lake, MI 49456 USA 800-235-7618 ~ Outside USA 231-798-1310...
Page 2
The material included in this technical manual is accurate at the date of publication. The intent of this manual is to assist. If further assistance is required, please contact the Bennett Technical Service Department at 1-800-423-6638. Bennett Marketing Services can be contacted by mail, facsimile, telephone or e-mail at the locations specified below: Bennett Pump Company...
Bennett T75 Operation, Service, & Parts Manual Table of Contents TABLE OF CONTENTS TABLE OF CONTENTS SAFETY INFORMATION General Information........................................4 Hazardous locations ........................................4 Codes and Standards ........................................4 Unauthorized Alteration of Bennett Products ..............................4 Abbreviations and Acronyms ..................................... 4 PRODUCT INTRODUCTION Features &...
Page 4
Bennett T75 Operation, Service, & Parts Manual Table of Contents Page Intentionally Left Blank...
FUEL ETHANOL IS POISONOUS AND SHOULD NOT BE INGESTED. Note: Bennett Pump highly recommends all technicians observe HSSE policies defined by the supplier. Bennett Pump does not impose any DISCONNECT ALL POWER, RELIEVE PRESSURE TO THIS EQUIPMENT, restrictions or additional requirements contained in Environmental AND ASSOCIATED COMPRESSOR DURING INSTALLATION, SERVICE, OR Standards®...
Petroleum Institute Recommended Practice RP 2003, Protection Against Ignitions Arising out of Static, Lightening, and Stray Currents. Service of the Bennett products and all accessories (e.g. Nozzles, Hoses, and Breakaways) must be performed by a technician who is trained in accordance to all codes, requirements, standards, and regulations.
The Type 75 pumping unit is a rotary vane type, flammable-liquid pump. They are provided with an integral strainer, pressure relief valve, air eliminator, and bypass valve, which is set to return liquid, under pressures exceeding 50 psi, to the suction side of the pump. For further information, please contact the Bennett Technical Service Department at 1-800-423-6638. FEATURES & CONSTRUCT ION The T75 pumping unit is fully compatible with the SB-100 Meter, compact and lightweight unit built with the following functions.
Bennett T75 Operation, Service, & Parts Manual Product Introduction EUROPEAN SPECIFICATI ONS Power Requirements @ Maximum Flow & Pressure ............... 22 gpm (80 lpm) at 700 RPM with 1 HP Motor (0.75kW) Maximum Flow Rate ......................................80 L/min Noise Level ..........................................72 dB Maximum Operating Pressure ....................................
Bennett T75 Operation, Service, & Parts Manual Product Introduction INLET & MOUNTING DIMENSIONS When installing units that contain a high alcohol product (e.g. E100). Confirm that the plumbing is designed to handle an alternative fuel. For multi- hose units, piping must align with the footprint.
Page 13
Bennett T75 Operation, Service, & Parts Manual Product Introduction TUBULAR OUTLET / MOTO R MOUNT OPTION FIGURE 7...
Page 14
Bennett T75 Operation, Service, & Parts Manual Product Introduction SIDE INLET OPTION INLET CENTER FIGURE 8...
The following section describes each of the main components of the T75 pumping unit and the interface characteristics at each component. Refer to the diagram on the next page for item locations. For any questions, please contact Bennett Technical Support at 1-800-423-6638.
Bennett T75 Operation, Service, & Parts Manual Operation THEORY OF OPERATION See Figure 10 for numbers in parenthesis. The product is drawn from the underground storage tank through the strainer screen of Filter (1). The Rotary Vane Pumping Unit (2) pressurizes the fluid.
DISPENSER! Use the table in each section to determine the cause and solution. For any additional questions, please contact Bennett Technical Support at 1-800-423-6638. PROBLEM 1: THE MOTOR STARTS BUT THE PUMP DOES NOT DELIVER FUEL.
Bennett T75 Operation, Service, & Parts Manual Troubleshooting PROBLEM 3: INACCURAT E DELIVERY Refer to the table below for a description of various causes of the problem and the solution. Cause Solution Control valve stuck open. Remove the 4-bolt control valve cover and free control valve.
Parts SECTION 5: PARTS PARTS Use the illustrations to determine the part required identified by an item number. Please contact Bennett Customer Service Department at 231- 719-6050 for any additional information. TO PLACE AN ORDER FO R PARTS To place an order for parts please contact us by mail, email, phone, fax, or web using the information provided below. Note: Verbal orders cannot be accepted.
Bennett T75 Operation, Service, & Parts Manual Parts T75 PUMPING UNIT ASSEMBLY Refer to the Type 75 Parts Lists on the following pages for part numbers, description, and comments. Note: Item numbers are not listed in numerical order.
Bennett T75 Operation, Service, & Parts Manual Parts TYPE 75 PUMPING UNIT PARTS LIST Refer to the Type 75 assembly on the previous page for reference number locations. Note: Not all parts are shown. Item Part No. Description Comment N159501S...
Bennett T75 Operation, Service, & Parts Manual Parts Continued from previous page… Item Part No. Description Comment N238301S Rotor & Shaft Assembly 6-Blade Standard 6 Blade Rotor 110245S Rotor & Shaft Assembly 10-Blade Side Inlet 10 Blade Rotor 110704 Rotor Blade N481203 Bypass Valve Spring &...
Page 25
Bennett T75 Operation, Service, & Parts Manual Page Intentionally Left Blank...
Page 26
Bennett 1218 E. Pontaluna Road, Spring Lake, MI 49456 USA 800-235-7618 ~ Outside USA 231-798-1310 sales@bennettpump.com ~ www.bennettpump.com...