3.38 MENU CODE 70: MARINA PULSER DELAY
Marina Dispensers Only!
• Program a delay between the valves turning ON and the pulsers turning ON.
• The delay allows the long hose to pressurize without the pulses being counted.
• May be set from 0 to 9 seconds and defaults to 0 seconds.
NOTE: The nozzle should remain closed during this delay, as any product dispensed during this delay will
not be included in the sale total.
To program:
Keypad
Retail Display
Action
Results
P d E L A y
70, Mode
- P - d E L A y
0 through 9
- - - - - - - 8
P d E L A y
Enter
C O d E
Cancel
3000 Series Operation Manual
Volume
Only Display
Results
P d E L A y 0
0
P - d E L A y - 8
P d E L A y 8
8
C O d E 0 0
0 0
Back to TOC
Lower PPV
Display Results
C O d E
C O d E
C O d E
S i d E -
Setup and Programming
Description
0 is default
Delay in seconds.
Enter Saves
Exit Menu Code