4.8 DIAGNOSTIC CODE 7: NOT USED

This code is not supported in this application.

4.9 DIAGNOSTIC CODE 8: LAST SALE LIMIT

Diagnostic mode 8 is intended for dispensers programmed to display Decimal Mode 0 and Gallons. This
function displays the sale limit, and amount of the last ten sales for the selected side. Money limits are
shown with two decimal digits and volume limits are shown with three decimal digits. Also, useful to
show the last limits that we were given from the POS in a prepay overrun.
Limit types that will display if they occur:
• 1 = Prepay Volume
• 2 = Prepay Money
• 3 = Allocation Limit
• 4 = Preset Money
• 5 = Preset Volume Amount
• 6 = Generic Loop Money Limit
• 7 = Overflow Display – The dispensed money amount exceeds the main display limits.
To view Last Sale Limits:
1. Press 0, Mode to enter diagnostics Mode 00.
2. Press 8, Enter.
a. Line 1 of the Main Display will show "TYPE (0-6)"
b. Line 2 will show the corresponding quantity.
c. The PPV Display will show "DIAG".
3. Press Enter to view the number of sales in descending chronological order (if available).
4. Press Cancel to exit this test.