3.4 MANAGER'S KEYPAD OPERATION
To setup and program the dispenser, follow this procedure:
1. Hang up all nozzles in their boots.
2. Unlock and open the upper door of side one. Side one is shown on Figure 1.2.
3. The Manager's Keypad is
shipped, attached to the
719 Control Board cover.
4. The Keypad cable should
be attached to the 719
board upon receiving the
dispenser. If that is not the
case, remove the 719
Control Board cover.
5. Connect the Manager's
Keypad to the cable
provided. Connect the
other end of the cable to
the J11 port on the 719
Control Board.
6. Press +/- and Enter
simultaneously until the
display changes. "Enter
Side 1" will be on the dispenser's side 1 display. The side 2 screen will display "OFFLINE".
7. Press Enter to access Manager Mode. The display appears as shown in Figure 3.2.
8. See Section 3.4 Manager's Access. To program a specific Menu Code, refer to the Table of
Contents for the page location.
3000 Series Operation Manual
Figure 3.1. 719 Control Board Cover.
Back to TOC
Setup and Programming

Manager

Keypad
Manager
Keypad cable
14