4.1

DIAGNOSTIC CODE 0

This test displays the design type, software revision level, and the software identification.
4.1.1 DESIGN TYPE
Displays the Control Board design type ("Type 7" is correct for a
Pacific 719 Control Board)
1. Switch the ON/OFF switch on the 719 Control Board to ON.
Hang the Pump Handles in the Nozzle Boots.
2. Press 0, Mode to enter diagnostics Mode 00.
3. Press Enter, line 1 of the Main Display should show
"DESIGN" and line 2 should show "TYPE 7".
4. Press Enter to advance to Diagnostic Menu 0.2.
4.1.2 SOFTWARE RELEASE NUMBER
5. Displays the current 719 software release version installed in the dispenser:
a. Display line one: "SOFt."
b. Display line two: Shows the software release version.
6. Press Enter to advance to Diagnostic Menu 0.3.
4.1.3 719 SOFTWARE I.D. NUMBER
Displays the current revision level of the installed 719 software:
a. Main Display line one: "719PAC"
b. Main Display line two: Shows the software revision level.
7. Press Enter to advance to Diagnostic Menu 0.4.
4.1.4 619 SOFTWARE I.D. NUMBER
Displays the software revision level of the lower I/O Board:
a. Main Display line one: "419"
b. Main Display line two: Shows the software revision level.
8. Press Enter to toggle through again or Cancel to exit this Diagnostics Code.
3000 Series Operation Manual
Back to TOC
Diagnostics
design
type 7
diag
Figure 4.1. Design Type Display