3.18 MENU CODE 12: PRE-CHARGE TIME
NOTE: If programming a two-sided dispenser, changing one side will automatically change the second
side to the same value as the first.
3.18.1 PRE-CHARGE TIME
The Pre-Charge Time delays the charging of the dispenser control valves. This gives the leak detectors,
installed in the station plumbing system, time to check the systems for leaks.
NOTE: The minimum time is 2 seconds, and the maximum time is 9 seconds.
• Passcode required, see Section
Keypad
Retail Display
Action
Results
12, Mode
P r E C H A r 6
Select a time
P r E C H A r 6
frame
3.18.2 LAST SALE DISPLAY TIMEOUT
Last Sale Timeout sets the amount of time the last sale is shown on the Main Display before the
dispenser returns to the idle state.
Keypad
Retail Display
Action
Results
Enter
L A S t
S A L E 3 0
L A S t
0-9
S A L E 9 9
3000 Series Operation Manual
3.4 Menu Code 3: Manager
Volume Only
Display Results
P r E C H r 6 2
2
P r E C H r 6 - 1
1
Volume Only
Display Results
L S A L E 3 0
L S A L E 9 9
Menu Code 12
Continued
Back to TOC
Access.
Lower PPV
Display Results
Pre-Charge default setting
C O d E
Key in a time-delay. Enter
to save and cycle to next
C O d E
Lower PPV
Display Results
Last Sale Timeout default
C O d E
Key in a new time,
99 Seconds is the
C O d E
Setup and Programming
Description
is 2 seconds.
(Last Sale).
Description
is 30 seconds.
maximum.
28