E E P R O M S E T T I N G S

EEProm Definitions (Full description)

ADO - Advanced Door Opening setup

Sets the doors to open whilst traveling into the floor. The doors shall commence opening when the lift is within the
door zone and the MSU or MSD vane pending direction.
ADO EEPROM Advanced Door Opening.
00: 00000000 "Off – Default"
01: 00000001 "On"
ALP – Auxiliary Leveling Pump operation setup
For hydraulic lifts, ALP can be set to control SP3 relay to allow Up Re-Leveling using the Auxiliary Pump motor.
For "SP3" relay to energise when performing an Up Re level set ALP to "01" and DRV to "00", "02" or "05".
The contacts of SP3 may also be used to stop a secondary pump starting when Up Re-Leveling
If ALP is set to "01", SP3 shall NOT turn on for inspection.
ALP EEPROM Auxiliary Leveling Pump.
FF: 11111111 "Off"
01: 00000001 "On – operates SP3 for Up Re-Level or inspection"

ANS - Anti Nuisance setup

Set to the number of times a car call is answered without EDP (Electronic Doors Protection) activation before calls
are cancelled. Counter is reset to zero if either EDPF or EDPR is activated. If a hall call is present as well as a car
call, the counter will not increment.
ANS EEPROM Anti Nuisance.
00: 00000000 "Off"
03: 00000011 "On – operates after 3 car calls of no EDP in a row."
1e: 00011110 "On – operates after 30 car calls of no EDP in a row - Default"

BCC - Bottom Car Call setup

BCC
EEPROM
Bottom car call for the "BOT CALL" button on the circuit board (MASK)
First floor served for this lift only.
The controller shall enter a car call to this setting when the "BOT CALL' button on the circuit board is pressed.
80: 10000000 (Level 1)
40: 01000000 (Level 2)
20: 00100000 (Level 3)
10: 00010000 (Level 4)
08: 00001000 (Level 5)

BOT - Bottom floor setup

BOT EEPROM
Bottom number (VALUE)
Set value to lowest floor served. (01 to 05 valid values)
Lift resets to "BOT" value when BSL limit is activated.