Start Waveclean; Ending Waveclean - Henny Penny ClassicCombi Operating Instructions Manual

Table of Contents

Advertisement

Cleaning
C AR

5.3.4 Start WaveClean

Requirements
C L3
1 15

5.3.5 Ending WaveClean

C AR
52
NOTICE
Use additional cartridges if necessary:
If heavily soiled: use 2 two-in-one cartridges. Select "WaveClean
-
extra" ("CL3") cleaning level.
If scaled: use a two-in-one cartridge + clear rinse cartridge.
-
4. Close chamber door.
The Sta r t/ S t o p ( 5 ) LEDs are lit.
Display (9) shows the selected cleaning level.
Display (8) flashes "CAr".
Hard water and soft water taps are open
→ Press S t a r t / St o p ( 5 ).
The Sta r t/ S t o p ( 5 ) LEDs flash.
Display (9) shows the selected cleaning level.
Display (8) shows the remaining time.
The LEDs of the S t e p (1 3 ) button light up once cleaning has finished.
Display (8) flashes "CAr" ( "Cartridge").
1. Open the cooking chamber door.
2. Remove the empty cartridge.
3. Rinse thoroughly with the hand-held rinsing head to remove any
residues of cleaner or rinsing agent.
4. Close the chamber door again.
5. Press St e p ( 1 3 ) and confirm that the cartridge has been removed.
The Ste p ( 1 3 ) LEDs go dark.
Display (9) and display (8) go dark.
6. Switch off the unit.
7. Open the chamber door and leave it slightly ajar until the next use.
This will increase the life of the door seal.
No moisture will build up in the cooking chamber.