Standard Settings - Henny Penny ClassicCombi Operating Instructions Manual

Table of Contents

Advertisement

Operation

4.10 Standard settings

No.
Parameters
0
Time/date
6
Temperature reading
82
Preheat factor %
32
Time delay fan
24
Cooling waste steam
83
Hood after-run period
(optional) (sec.)
84
Beep time (sec.)
15
Altitude
96
Password
42
Display (8) shows the cooking time or the target core temperature.
The unit is already pre-configured when delivered.
The values listed in the following table can be adjusted individually.
Pre-set value
Possible settings
The operator's local
t1: 0–23
time
t2: 0–59
d1: 1–31
d2: 1–12
d3: 8–99
°C
°C/°F
15
0–30 %
"oFF"
Off/On
"Std"
"Lo"/"Std"/"Hi"
60
0–600
20
0–180
0
0–3
111
000–500
Operating instructions
ClassicCombi
Explanation
t1=hours
t2=minutes
d1=day
d2=month
d3=year
With units without a real-time clock (op-
tional), these settings are lost if the unit
is switched off.
Temperature reading in °F does not de-
pend on having the English display text.
Increase the preheat factor for full loads
of large masses (roasts, loaves of bread)
to prevent the temperature in the cooking
chamber from falling too much.
If "On" , the fan will run in cycles during
the time delay period.
Setting "Lo": Minimum water consump-
tion, higher condensation temperature,
greater volume of waste steam.
Setting "Hi": Maximum water consump-
tion, low condensation temperature, low
volume of waste steam.
At this setting, the drain temperature is <
60 °C (140 °F).
After-run period for the extraction hood
(optional).
Length of the acoustic signal (in seconds).
0=signal off
For the altitude (above sea level), inquire
at the nearest weather station. Set to
0–500 m (1,640 ft.) if the altitude is not
known.
0=0–500 m (1,640 ft.)
1=501 m (1,644 ft.)–1000 m (3,281 ft.)
2=1001 m (3,284 ft.)–1500 m (4,921
ft.)
3= > 1500 m (4,921 ft.)
Individual passwords can be configured
in this area.
Global Foodservice Solutions

Advertisement