Complete Hardware Guide for EX3300 Ethernet Switches
Table 32: Parts and Tools Required for Connecting an EX Series Switch to Earth
Ground (continued)
Earthing
Terminal
Grounding Cable

Switch

Location
Requirements
EX8216
Two
2 AWG (33.6 mm²),
earthing
minimum 60°C wire,
terminals:
or as permitted by
the local code
Left side
of
chassis
Rear
panel of
chassis
EX9204
Rear panel
One 6 AWG (13.3
of chassis
mm²), minimum
60°C wire, or one
that complies with
the local code
EX9208
Rear panel
One 6 AWG (13.3
of chassis
mm²), minimum
60°C wire, or one
that complies with
the local code
EX9214
Rear panel
One 6 AWG (13.3
of chassis
mm²), minimum
60°C wire, or one
that complies with
the local code
Special Instructions to Follow Before Connecting Earth Ground to a Switch
Table 33: Special Instructions to Follow Before Connecting Earth Ground to a Switch
Switch
Special Instructions
EX3200
NOTE:
Some early variants of EX3200 switches for which the Juniper Networks model number on the label
next to the protective earthing terminal is from 750-021xxx through 750-030xxx require 10-24x.25 in. screws.
102
Grounding Lug
Specifications
Panduit
LCD2-14A-Q or
equivalent
—provided
Thomas&Betts
LCN6-14 or
equivalent—
provided
Thomas&Betts
LCN6-14 or
equivalent—
provided
Thomas&Betts
LCN6-14 or
equivalent—
provided
Table 33 on page 102
lists the special instructions that you might need to follow before
connecting earth ground to a switch.
Screws and
Washers
Screwdriver
Two ¼-20 x
Phillips (+)
0.5 in. screws
number 2
with #¼"
split-washer
—provided
Two #¼" flat
washers—
provided
Two ¼-20
Phillips (+)
x 0.5 in. screws
number 2
with #¼"
split-washer—
provided
Two #¼" flat
washers—
provided
Two ¼-20
Phillips (+)
x 0.5 in. screws
number 2
with #¼"
split-washer—
provided
Two #¼" flat
washers—
provided
Two ¼-20
Phillips (+)
x 0.5 in. screws
number 2
with #¼"
split-washer—
provided
Two #¼" flat
washers—
provided
Copyright © 2015, Juniper Networks, Inc.
Additional
Information
See
"Special
Instructions to
Follow Before
Connecting Earth
Ground to a Switch"
on page
102.
See Grounding
Cable and Lug
Specifications for
EX9200 Switches.
See Grounding
Cable and Lug
Specifications for
EX9200 Switches.
See Grounding
Cable and Lug
Specifications for
EX9200 Switches.