Oil Pressure Regulator (Bypass) Valve Inspection; Stator Cover Oil Seal Inspection - Polaris RANGER ETX 2015 Owner's Manual

Table of Contents

Advertisement

1. Remove the stator cover.
q
2. Remove the bolts
securing the oil pump cover to
the stator cover.
3. Grasp the oil pump shaft
remove the shaft, oil pump cover
pump gerotor.
NOTE
w
The gerotor set has
orientation dots that must be
installed inward upon assembly.
4. Remove the center gerotor
from the oil pump cover.
NOTE
There is a spacer in between the inner oil pump gerotor
and the oil pump cover.
5. Remove the oil pump gerotor that is in the stator
cover (if needed).
6. Clean the gerotor to remove oil.
7. Inspect surfaces of pump cavity in stator cover and
surface of pump cover for scoring or wear.
8. Inspect gerotor for scoring or other damage. Replace
parts as a set if damaged.
OIL PRESSURE REGULATOR (BYPASS)
VALVE INSPECTION
The oil pressure regulator (bypass) valve is located in the
stator cover.
1. Remove the retaining ring
pressure regulator piston in the stator cover.
w
2. Remove the washer
, spring
3. Replace the oil pressure regulator piston if it binds,
sticks or does not operate smoothly.
4. Thoroughly clean the piston and bore.
9926806 R03 - 2015 - 2016 RANGER ETX / 570 2-SEAT 2015 - 2016 RANGER 570 CREW Service Manual
© Copyright Polaris Industries Inc.
t
and pull it outward to
w
and inner oil
e
r
t
, pin
and shaft
q
securing the oil
e
r
and piston
.
ENGINE / COOLING SYSTEM
5. Coat the piston with clean engine oil and insert it into
the stator cover until fully seated.
6. Install the spring, washer and retaining ring.

STATOR COVER OIL SEAL INSPECTION

q
Inspect the oil seal
whenever the stator cover is
removed from the engine. Remove and replace if wear is
found.
When installing a new seal, press seal in with lips facing
towards cover. Press until seal is fully seated in bore
3
w
.
3.75