Polaris RANGER ETX 2015 Owner's Manual page 251

Table of Contents

Advertisement

1. Remove the stator cover (Refer to "Stator Cover
Removal", page 3.155)
2. Remove the two oil pump sprocket bolts and
washers. Discard the bolts and replace with new for
assembly. Remove the sprockets and chain from the
engine.
3. Inspect the oil pump chain for worn or missing rollers
or damage. Chain should be replaced as a set with
sprockets if sprocket teeth are worn.
NOTE
The larger oil pump sprocket
shaft extension, the smaller oil pump sprocket
mounts to the oil pump shaft.
9926806 R03 - 2015 - 2016 RANGER ETX / 570 2-SEAT 2015 - 2016 RANGER 570 CREW Service Manual
© Copyright Polaris Industries Inc.
s
mounts to the balance
d
ENGINE / COOLING SYSTEM
4. Remove the upper oil pump sprocket spacer.
5. Remove the three bolts securing the oil pump cover
to the crankcase.
6. Grasp the oil pump shaft and pull it outward to
remove the shaft, oil pump cover and inner oil pump
geroter. This will prevent the oil pump drive pin from
falling out and into the crankcase.
NOTE
The gerotor set has two orientation dots that must be
installed inward upon assembly
(Figure 1 on the next page).
7. Remove the center geroter, pin and shaft from the oil
pump cover.
NOTE
f
There is a spacer
in between the inner oil pump
geroter and the oil pump cover.
8. Remove the oil pump geroter that is in the engine
case (if needed).
9. Clean the geroters to remove oil.
3
3.159