1. Functions
time
HostState[2:0]
Don't care
DetectDevChirpNG
DetectDevChirpOK
ResetCmp
XcvrSelect[1:0]
HS/FS
TermSelect
OpMode[1:0]
PortSpeed[1:0]
LineState[1:0]
DP / DM
Fig. 1-56 Detect device chirp NG timing (with chirp completion disable set to 1)
124
(12) The device switches to HS mode on detecting the host chirp (T7).
The change in chirp height after point T8 indicates that device HS
termination is enabled. The chirp is approximately 800 mV when the
device is in FS mode and approximately 400 mV when in HS mode.
(13) The host ends the chirp (T9).
(14) Reset is ended (T10).
(15) Issues reset completion status notification (H_SIE_IntStat_1.ResetCmp)
(T10).
T0
T1
T2
RESET
HS
Normal Operation
SE0
'J' State
SE0
Device K
Reset
Upstream
Port Chirp
T3
T4
T5
T6
T7
Disable BS and NRZI
HS
SE0
K
J
K
J
K
J
Downstream
Port Chirp
EPSON
T8
T9
T10
T11
K
J
K
J
Device HS Mode
S2R72V18 Technical Manual (Rev.1.00)
T12
OPERATIONAL
Normal Operation
SOF
Operational