Program Example for the Fast Logic Function

This section describes the program examples for when the fast logic function is used.
Turning off the module power supply returns Fast logic setting Y (address: 0110H to 011FH, 0130H to 013FH, 0210H
to 021FH) to the default value (Disable (0)). (The parameter is not stored in the nonvolatile memory.)
Thus, when the fast logic function is set with a program, not by the parameter setting of an engineering tool, the
parameter can be set again easily.
10.5.1
Program example for the fast logic function
(1) System configuration
(a) Assignment of link devices
The assignment of link devices is the same as that in the following section.
• Assignment of link devices ( Page 215, Section 10.3 (1) (a))
(2) Programming condition
When both X2 and X3 of the main input module are turned on, Y11 of the extension output module is turned on.
When both X4 and X5 are turned on, Y12 of the extension output module is turned on.
Power supply module
CPU module (Q10UDHCPU)
Master module (QJ71GF11-T2)
Network No.1
CHAPTER 10 PROGRAMMING
Station No.1
Main input module (NZ2GF2B1-16D)
Extension output module (NZ2EX2B1-16T)
Y11 Lamp
Y12 Lamp
X2 Pressing button
X3 Pressing button
X4 Pressing button
X5 Pressing button