4.7

List of Remote Register

This section lists remote registers for a master/local module.
The remote registers shown are the example with the remote registers of the I/O module assigned to the remote
registers of RWr0 to RWr33 and RWw0 to RWw33.
The remote registers are assigned in station-based units regardless of the main module or extension module.
Remote register (RWr) is the information input from the I/O module to the master/local module.
Remote register (RWw) is the information output from the master/local module to the I/O module.
For details on the remote register, refer to the following.
• Details of Remote Registers ( Page 257, Appendix 2)
(1) Main input module
Remote register (RWr)
Signal direction: I/O module  Master/local module
Device number
RWr0
Module status area
RWr1
Error code
RWr2
Warning code
RWr3
Function selection status flag
RWr4
Use prohibited
*2
Output Y current value Y10 to Y1F
RWr5
*3
Output Y current value Y20 to Y2F
RWr6
RWr7
Use prohibited
RWr8
Use prohibited
*2
Output Y ON information Y10 to Y1F
RWr9
*3
Output Y ON information Y20 to Y2F
RWrA
RWrB
Use prohibited
RWrC
Use prohibited
*2
Output Y OFF information Y10 to Y1F
RWrD
*3
Output Y OFF information Y20 to Y2F
RWrE
RWrF
Use prohibited
RWr10
Use prohibited
RWr11
Use prohibited
RWr12
Use prohibited
*1
Use prohibited
RWr13
*4
Synchronous input timing information X0 OFF to ON
RWr14
*4
Synchronous input timing information X0 ON to OFF
RWr15
*4
Synchronous input timing information X1 OFF to ON
RWr16
*4
Synchronous input timing information X1 ON to OFF
RWr17
*4
Synchronous input timing information X2 OFF to ON
RWr18
*4
Synchronous input timing information X2 ON to OFF
RWr19
*4
Synchronous input timing information X3 OFF to ON
RWr1A
*4
Synchronous input timing information X3 ON to OFF
RWr1B
*4
Synchronous input timing information X4 OFF to ON
RWr1C
*4
Synchronous input timing information X4 ON to OFF
RWr1D
*4
Synchronous input timing information X5 OFF to ON
RWr1E
*4
Synchronous input timing information X5 ON to OFF
RWr1F
106
Name
Remote register (RWw)
Signal direction: Master/local module  I/O module
Device number
RWw0
Module operation area
RWw1
Use prohibited
RWw2
Use prohibited
RWw3
Function selection setting flag
RWw4
Use prohibited
RWw5
Use prohibited
RWw6
Use prohibited
RWw7
Use prohibited
RWw8
Use prohibited
*2
Output Y ON information clear request Y10 to Y1F
RWw9
*3
Output Y ON information clear request Y20 to Y2F
RWwA
RWwB
Use prohibited
RWwC
Use prohibited
*2
Output Y OFF information clear request Y10 to Y1F
RWwD
*3
Output Y OFF information clear request Y20 to Y2F
RWwE
RWwF
Use prohibited
RWw10
Use prohibited
RWw11
Use prohibited
RWw12
Use prohibited
*1
Use prohibited
RWw13
RWw14
Use prohibited
RWw15
Use prohibited
RWw16
Use prohibited
RWw17
Use prohibited
RWw18
Use prohibited
RWw19
Use prohibited
RWw1A
Use prohibited
RWw1B
Use prohibited
RWw1C
Use prohibited
RWw1D
Use prohibited
RWw1E
Use prohibited
RWw1F
Use prohibited