Mitsubishi Electric NZ2GF2B1-16D User Manual page 34

Cc-link ie field network remote i/o module
Table of Contents

Advertisement

No.
Name
1)
Station number setting switch
X0 LED to XF LED (green)
Y0 LED to YF LED (green)
I/O PW LED (green)
RUN LED (green)
2)
PW LED (green)
MODE LED (green)
ERR. LED (red)
D LINK LED (green)
P1
L ER LED (red)
LINK LED (green)
3)
P2
L ER LED (red)
LINK LED (green)
Terminal block for module power
4)
supply and FG
5)
DIN rail hook
Terminal cover
6)
I/O terminal block
7)
Extension connector cover
Connector for power supply and
8)
FG
9)
Sensor connector (e-CON)
10)
MIL connector
*1
The status of actual input signals that are externally input is indicated on the LEDs regardless of the setting of the input
OFF delay function.
*2
Output commands from the module are indicated on the LEDs regardless of the status of the external power supply.
32
A rotary switch for the following setting and test.
• Station Number Setting ( Page 138, Section 7.1)
• Unit Test (Page 246, Section 12.4)
When operating the station number setting switch, use a flathead screwdriver with 3.5mm or less width of the tip.
Indicates the ON/OFF status of the inputs.
• On: Input ON
• Off: Input OFF
Indicates the ON/OFF status of the outputs.
• On: Output ON
• Off: Output OFF
Indicates the status of the power supply from the external power supply.
• On: External power supply ON
• Off: External power supply OFF
Indicates the operating status of the I/O module.
• On: Operating normally.
• Off: A major error has occurred.
Indicates the power supply status of the main I/O module.
• On: Power supply ON
• Off: Power supply OFF
Indicates the mode of the main I/O module.
• On: Online mode
• Flashing: Unit test mode
• Off: The unit test is completed.
Indicates the error status of the main I/O module.
• On: A module error has occurred.
• Flashing: A minor error has occurred.
• Off: Operating normally.
Indicates the data link status of the main I/O module.
• On: Data link in operation. (cyclic transmission in progress)
• Flashing: Data link in operation. (cyclic transmission stopped)
• Off: Data link not performed. (disconnected)
PORT1 connector for CC-Link IE Field Network (RJ45 connector)
Connect an Ethernet cable. ( Page 153, Section 7.6)
There are no restrictions on the connection order of the cables for the P1 connector and P2 connector.
• On: Module received abnormal data, or module performing loopback
• Off: Module received normal data, or module not performing loopback
• On: Linkup in progress
• Off: Linkdown in progress
PORT2 connector for CC-Link IE Field Network (RJ45 connector)
Connect an Ethernet cable. ( Page 153, Section 7.6)
There are no restrictions on the connection order of the cables for the P1 connector and P2 connector.
(Same as the LEDs of "P1" connector)
A terminal block to connect the module power supply (24VDC) and FG.
A hook to mount an I/O module on a DIN rail
Covers for preventing electric shock while the power is on
A terminal block for I/O power supply and I/O signals
A cover to protect a connector of an extension module.
A connector to connect the module power supply (24VDC), external power supply for I/O part, and FG
Connector for I/O signals