Appendix 2
This section lists remote registers for a master/local module.
The following shows an assignment example of remote registers with the remote registers of the IO-Link module assigned to
RWr0 to RWr83 and RWw0 to RWw83. (This example assumes that IO-Link devices with the process data size of 16 words
are connected to all the channels from 1 to 8 of the IO-Link module.)
The remote registers are assigned in station-based units.
Remote register (RWr) is the information input from the IO-Link module to the master/local module.
Remote register (RWw) is the information output from the master/local module to the IO-Link module.
Do not read or write data from/to any "Use prohibited" remote registers. Doing so may cause an accident due
to incorrect output or malfunction.

List of remote register

Remote register (RWr)
Signal direction: IO-Link module  Master/local module
Device number
RWr0
RWr1
RWr2
RWr3
RWr4
to
RWr4+(n1-1)
RWr+(m2+1)
to
RWr(m2+1)+(n2-1)
RWr+(m3+1)
to
RWr(m3+1)+(n3-1)
RWr+(m4+1)
to
RWr(m4+1)+(n4-1)
RWr+(m5+1)
to
RWr(m5+1)+(n5-1)
RWr+(m6+1)
to
RWr(m6+1)+(n6-1)
RWr+(m7+1)
to
RWr(m7+1)+(n7-1)
RWr+(m8+1)
to
RWr(m8+1)+(n8-1)
APPX
138

Appendix 2 Remote Registers

Remote Registers
Name
Module status area
Error code
Warning code
Use prohibited
Channel 1 input process data
• n1: Data size of channel 1
Channel 2 input process data
• m2: RWr4+(n1-1)
• n2: Data size of channel 2
Channel 3 input process data
• m3: RWr(m2+1)+(n2-1)
• n3: Data size of channel 3
Channel 4 input process data
• m4: RWr(m3+1)+(n3-1)
• n4: Data size of channel 4
Channel 5 input process data
• m5: RWr(m4+1)+(n4-1)
• n5: Data size of channel 5
Channel 6 input process data
• m6: RWr(m5+1)+(n5-1)
• n6: Data size of channel 6
Channel 7 input process data
• m7: RWr(m6+1)+(n6-1)
• n7: Data size of channel 7
Channel 8 input process data
• m8: RWr(m7+1)+(n7-1)
• n8: Data size of channel 8
Remote register (RWw)
Signal direction: Master/local module  IO-Link module
Device number
Name
RWw0
Module operation area
RWw1
Use prohibited
RWw2
Use prohibited
RWw3
Use prohibited
RWw4
Channel 1 output process data
to
• n1: Data size of channel 1
RWw4+(n1-1)
RWw+(m2+1)
Channel 2 output process data
to
• m2: RWw4+(n1-1)
RWw(m2+1)+(n2-1)
• n2: Data size of channel 2
RWw+(m3+1)
Channel 3 output process data
to
• m3: RWw(m2+1)+(n2-1)
RWw(m3+1)+(n3-1)
• n3: Data size of channel 3
RWw+(m4+1)
Channel 4 output process data
to
• m4: RWw(m3+1)+(n3-1)
RWw(m4+1)+(n4-1)
• n4: Data size of channel 4
RWw+(m5+1)
Channel 5 output process data
to
• m5: RWw(m4+1)+(n4-1)
RWw(m5+1)+(n5-1)
• n5: Data size of channel 5
RWw+(m6+1)
Channel 6 output process data
to
• m6: RWw(m5+1)+(n5-1)
RWw(m6+1)+(n6-1)
• n6: Data size of channel 6
RWw+(m7+1)
Channel 7 output process data
to
• m7: RWw(m6+1)+(n6-1)
RWw(m7+1)+(n7-1)
• n7: Data size of channel 7
RWw+(m8+1)
Channel 8 output process data
to
• m8: RWw(m7+1)+(n7-1)
RWw(m8+1)+(n8-1)
• n8: Data size of channel 8