24 V input terminal block
Used for 24 VDC power supply.
Compatible wire specifications: Solid wire 0.2 to 2.5 mm
Important
• Wiring with the power on could result in a short-circuit or electric shock. Wire with the power off.
• Wire the power supply separate from other devices. Wiring together with other devices or using the same duct could
cause a false operation or damage the sensor.
• Do not turn off the power during initial processing immediately after the Sensor Controller power is turned on, as the
memory inside the Sensor Controller is being accessed. This may corrupt the data.
• Securely fasten the terminal block to prevent injury when you press in the release button with a screwdriver.
• Use the electric cable within 2m.
1
Remove 24 V input terminal block from the Sensor
Controller.
42
Basic Operations for Displaying Measurement Results
2
Stranded wire 0.2 to 2.5 mm
Stranded wire with rod terminal(no plastic sleeve) 0.25-2.5 mm
Stranded wire with rod terminal(with plastic sleeve) 0.25-2.5 mm
AWG 24-12
Pin processed length 10(±0.5) mm
No.
Signal name
1
24 VDC ( - )
2
24 VDC (+)
Class
Name
Power Supply
24 VDC (+)
24 VDC ( - )
2
Description
Terminal for external power supply (24 V)
Terminal for external power supply (0 V)
2
2
ZW-8000/7000/5000
User's Manual