Omron ZW-8000 Series User Manual page 219

Confocal fiber type displacement sensor
Table of Contents

Advertisement

I/O setting
Digital output
[I/O]
[DIGTAL]
(cont'd)
*1. For more detail, refer to the following.
"6-1 Connecting Parallel I/O" described in Displacement Sensor ZW-8000/7000/5000 series Confocal Fiber Type
Displacement Sensor User's Manual for Communications Settings (Z363)
ZW-8000/7000/5000
User's Manual
Setting
Option/Setting Range
OFF[OFF] / TASK1 [TASK1] / TASK2
[TASK2] / TASK3 [TASK3]* / TASK4
[TASK4] /Amount of emitted light
[LIGHT] (Area1) / Peak amount of
received light (Exposure control edge)
[PEAK.CT] (Area1) / Peak amount of
received light (1st surface) [PEAK.1]
(Area1) / Peak amount of received
light (2nd surface) [PEAK.2] (Area1) /
Peak amount of received light (3rd
surface) [PEAK.3] (Area1) / Peak
amount of received light (4th surface)
[PEAK.4] (Area1) Amount of emitted
light [LIGHT] (Area2) / Peak amount
of received light (Exposure control
Output data 3
edge) [2.PEAK.C] (Area2) / Peak
[OUT3]
amount of received light (1st surface)
[2.PEAK.1] (Area2) / Peak amount of
received light (2nd surface)
[2.PEAK.2] (Area2) / Peak amount of
received light (3rd surface)
[2.PEAK.3] (Area2) / Peak amount of
received light (4th surface)
[2.PEAK.4] (Area2)
Measurement state[MS.CON] (ZW-
8000@ only)
Area1 Reflection
power[REF.PW1](ZW-8000@ only)/
Area2 Reflection
power[REF.PW2](ZW-8000@ only)
OFF[OFF] / TASK1 [TASK1] / TASK2
[TASK2] / TASK3 [TASK3] / TASK4
[TASK4]* /Amount of emitted light
[LIGHT] (Area1) / Peak amount of
received light (Exposure control edge)
[PEAK.CT] (Area1) / Peak amount of
received light (1st surface) [PEAK.1]
(Area1) / Peak amount of received
light (2nd surface) [PEAK.2] (Area1) /
Peak amount of received light (3rd
surface) [PEAK.3] (Area1) / Peak
amount of received light (4th surface)
[PEAK.4] (Area1) Amount of emitted
light [LIGHT] (Area2) / Peak amount
of received light (Exposure control
Output data 4
edge) [2.PEAK.C] (Area2) / Peak
[OUT4]
amount of received light (1st surface)
[2.PEAK.1] (Area2) / Peak amount of
received light (2nd surface)
[2.PEAK.2] (Area2) / Peak amount of
received light (3rd surface)
[2.PEAK.3] (Area2) / Peak amount of
received light (4th surface)
[2.PEAK.4] (Area2)
Measurement state[MS.CON] (ZW-
8000@ only)
Area1 Reflection
power[REF.PW1](ZW-8000@ only)/
Area2 Reflection
power[REF.PW2](ZW-8000@ only)
0x7FFFFFFF[MAX] /
Clamp value
999999999[99999] / 0 [0] /
[CLAMP]
-999999999 [-99999] /
0x80000000[MIN]*
Search from Menu Tree
* default value
Pages
*1
*1
*1
217

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 seriesZw-5000 series

Table of Contents