Confocal fiber type displacement sensor
Table of Contents

Advertisement

Sensing
EdgeTracks
setting
[EDGE.TR]
[SENS]
(cont'd)
Measurement
TASK1
setting
[TASK1]
[MEAS]
ZW-8000/7000/5000
User's Manual
: This is displayed only when the 2 area mode is selected in [Measurement Area].
Area
[REGION]
Measurement
Height *
item
[HEIGHT]
[ITEM]
Thick
[THICK]
Calculation
[CALC]
None
[NONE]
Filter
[FILTER]
The grayed-out settings can only be used with ZW-8000@.
Setting
Option/Setting Range
EdgeTracks
OFF [OFF]/ON [ON]
[EDGE.TR]
Area Teach
[TEACH]
Edge1
0.000 to 65.535 mm
Track Width
(default value: 10% of measuring range) p.135
[TR.WID1]
Edge2
0.000 to 65.535 mm
Track Width
(default value: 10% of measuring range) p.135
[TR.WID2]
Edge3
0.000 to 65.535 mm
Track Width
(default value: 10% of measuring range) p.135
[TR.WID3]
Edge4
0.000 to 65.535 mm
Track Width
(default value: 10% of measuring range) p.135
[TR.WID4]
Area
Area 1 [REG.NO1]*/ Area 2
[REGION]
[REG.NO2]
Edge 1st [EDGE1]/Edge 2nd
Measurement
surface
[EDGE2]/Edge 3rd [EDGE3]/Edge
[SUR]
4th [EDGE4]/Light Peak [PEAK] *
Edge 1st [EDGE1]/Edge 2nd
Surface 1
[EDGE2]/Edge 3rd [EDGE3]/Edge
[TOP]
4th [EDGE4]/Light Peak [PEAK] *
Edge 1st [EDGE1]/Edge 2nd
Surface 2
[EDGE2]/Edge 3rd [EDGE3]/Edge
[END]
4th [EDGE4]/Light Peak [PEAK] *
Parameter K
-999.999999 to 999.999999 mm
[PARAM.K]
(default value: 0)
Parameter m
-10.0 to 10.0 (default value: 0)
[PARAM.M]
Parameter n
-10.0 to 10.0 (default value: 0)
[PARAM.N]
None [OFF]*/TASK1 [TASK1]/
Parameter X
TASK2 [TASK2]/TASK3 [TASK3]/
[PARAM.X]
TASK4 [TASK4]
None [OFF]*/TASK1 [TASK1]/
Parameter Y
TASK2 [TASK2]/TASK3 [TASK3]/
[PARAM.Y]
TASK4 [TASK4]
Median
OFF[OFF]*/3 times [3]/9 times [9]/15
[MEDIAN]
times [15]/31 times [31]
Average
1/2/4/8/16/32/64/128/256/512/1024*/
[AVE]
2048/4096/8192/16384
Differential
Off [OFF]*/On [ON]
[DIFFER]
Differential
cycle
0.02 to 5000ms (default value: 0.02)
[CYCLE]
Off [OFF]*/
Frequency
Lowpass [LO.PASS]/
[FREQ]
Highpass [HI.PASS]/
Bandpass [BD.PASS]
Cutoff
Refer to explanation page of Cutoff
frequency
frequency