Omron ZW-8000 Series User Manual page 86

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Output circuit
Item
Model
*1
Output type
Output voltage
Load current
ON residual voltage
ON leakage current
*2
Internal circuit diagram
*1 NPN/PNP dual type. According to the specifications of the external equipment, ensure proper wiring.
*2 Below is a table giving the COM_OUT (output common) and output signal connection correspondence.
Terminal name COM_OUT1
HIGH
PASS
LOW
Output signal
name
ALARM
BUSY
ENABLE
Important
• Connect a load that matches the output specifications. Short-circuit can cause sensor breakdown.
• Keep the load current less than or equal to the specification value. Exceeding the specification value could cause
damage to the output circuit.
84
Wiring
Specifications
ZW-8000@/7000@/5000@
For NPN connection
21.6 to 30 VDC
50 mA max.
2 V max.
0.1 mA max.
Internal
circuit
COM_OUT2
BANK_OUT1
BANK_OUT2
BANK_OUT3
For PNP connection
21.6 to 30 VDC
50 mA max.
2 V max.
0.1 mA max.
Output
terminals
L
Load
Internal
+
circuit
COM_OUT1/2/3
COM_OUT3
STABILITY
LOGERR
LOGATAT
SYNCFLG/TRIGBUSY
TASKSTAT
COM_OUT1/2/3
+
Load
L
Output
terminals
ZW-8000/7000/5000
User's Manual