Omron ZW-8000 Series User Manual page 109

Confocal fiber type displacement sensor
Table of Contents

Advertisement

4
Set the trigger condition.
• When the trigger target is "Data slope"
Item
Setting item
Trigger condition Condition
Judgment
• When the trigger target is "Data window (In)"
Item
Setting item
Trigger condition Judgment value
1
Judgment value
2
• When the trigger target is "Data window (out)"
Item
Setting item
Trigger condition Judgment value
1
Judgment value
2
• When the trigger target is "I/O"
Item
Setting item
Trigger condition Condition
ZW-8000/7000/5000
User's Manual
Range
Description
=
When the measurement results are the same value as the
judgment value, the trigger condition is considered to have
been met.
When the measurement results are a different value from
the judgment value, the trigger condition is considered to
have been met.
>
When the measurement results are greater than the
judgment value, the trigger condition is considered to have
been met.
When the measurement results are greater than or equal to
the judgment value, the trigger condition is considered to
have been met.
<
When the measurement results are less than the judgment
value, the trigger condition is considered to have been met.
When the measurement results are less than or equal to
the judgment value, the trigger condition is considered to
have been met.
-999.999999 to
This is the judgment value for the measurement results.
999.999999 mm
Range
Description
-999.999999 to
When the measurement results are greater than or equal to
999.999999 [mm]
judgment value 1 and less than or equal to judgment value
2, the trigger condition is considered to have been met.
-999.999999 to
999.999999 [mm]
Range
Description
-999.999999 to
When the measurement results are less than judgment
999.999999 [mm]
value 1 or greater than judgment value 2, the trigger
condition is considered to have been met.
-999.999999 to
999.999999 [mm]
Range
Description
TRUE (rising)
When the I/O signal rises, the trigger condition is
considered to have been met.
False (falling)
When the I/O signal falls, the trigger condition is considered
to have been met.
Displaying measured values in graphs
107