Omron ZW-8000 Series User Manual page 81

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Class
Name
Parallel
HIGH output
output
PASS output
LOW output
ALARM output
BUSY output
ENABLE output
BANK_OUT output
SYNCFLG/TRIGBUSY
output
STABILITY output
LOGSTAT output
LOGERR output
TASKSTAT output
In FUNC mode, output of each signals are the followings;
• BUSY output Turns ON
BANK_OUT Outputs the current bank number
Other signals Turns OFF
ZW-8000/7000/5000
User's Manual
Description
This outputs judgment results - HIGH (HIGH threshold values < Measured value).
This outputs judgment results - PASS (LOW threshold values ≤ Measured value ≤ HIGH
threshold values).
This outputs judgment results - LOW (LOW threshold values > Measured value).
This turns ON when there is a system error.
This turns ON during sampling with the hold function enabled. It allows you to check
whether or not the self-trigger is functioning correctly.
It also turns ON during bank switching.
This turns ON when the sensor is ready for measurement.
This output is interlocked with the ENABLE indicator.
This outputs the currently specified bank number.
It expresses the bank number in combinations of BANK_OUT1, 2 and 3.
Bank Number BANK_OUT1
BANK1
OFF
BANK2
ON
BANK3
OFF
BANK4
ON
BANK5
OFF
BANK6
ON
BANK7
OFF
BANK8
ON
In the internal/PDO synchronized mode, this output operates as SYNCFLG. This turns ON
when measurement synchronization processing is executed by SYNC input and the state
changes to one where normal measurement values can be output.
In the external synchronous measurement mode, this output operates as TRIGBUSY. This
turns ON while a measurement by TRIG input is being performed. The next TRIG input
cannot be turned ON until this turns OFF.
This turns ON when 1surface is within the measurement range.
This output is interlocked with the STABILITY indicator.
This turns ON while internal logging is in execution.
This turns ON when internal logging fails. Turns ON when the maximum number of logging
results are saved and you try to execute internal logging. If the LOGGING signal turns OFF,
LOGERR signal is also turned OFF.
This turns ON when the measurement value is finalized.
BANK_OUT2
BANK_OUT3
OFF
OFF
OFF
OFF
ON
OFF
ON
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
79
Wiring

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Zw-7000 seriesZw-5000 series

Table of Contents