Omron ZW-8000 Series User Manual page 217

Confocal fiber type displacement sensor
Table of Contents

Advertisement

Measurement
TASK1
setting
[TASK1]
[MEAS]
(cont'd)
(cont'd)
TASK2
[TASK2]
TASK3
[TASK3]
TASK4
[TASK4]
Non-measurement
I/O setting
setting
[I/O]
[HLD.RST]
TIMING
input mode
[TIM.MOD]
Judgment
[JUDGE]
*1. For more detail, refer to the following.
"6-1 Connecting Parallel I/O" described in Displacement Sensor ZW-8000/7000/5000 series Confocal Fiber Type
Displacement Sensor User's Manual for Communications Settings (Z363)
*2. Only [OFF] is allowable in External/PDO synchronized mode.
*3. First enter the number and set the decimal point.
*4. KEEP is the initial value for ZW-8000 and CLAMP is the initial value for ZW-7000/5000.
ZW-8000/7000/5000
User's Manual
Threshold
Teaching
[JUDGE]
[TEACH]
Direct
[DIRECT]
(Same content as TASK1)
Default value of measurement item is [NONE]
(Same content as TASK1)
Default value of measurement item is [NONE]
(Same content as TASK1)
Default value of measurement item is [NONE]
Output target
[OUTPUT]
Hysteresis
[HYS]
Timer
[TIMER]
The grayed-out settings can only be used with ZW-8000@.
Setting
Option/Setting Range
High
-999.999999 to 999.999999 mm
threshold
(default value: +25% of measuring
[H.JUDGE]
range)
-999.999999 to 999.999999 mm
Low threshold
(default value: -25% of measuring
[L.JUDGE]
range)
High
-999.999999 to 999.999999 mm
threshold
(default value: +25% of measuring
[H.JUDGE]
range)
-999.999999 to 999.999999 mm
Low threshold
(default value: -25% of measuring
[L.JUDGE]
range)
Non-measurement
setting
Keep [KEEP]/Clamp [CLAMP]*4
[HLD.RST]
Keep count
specification
OFF[OFF]/ON[ON]*
flag
[KEEP.EN]
1 to 16382
Keep count
[KEEP.CN]
(default value: 8)
Number of
1 to 16382
restorations
(default value: 1 )
[RESR.CN]
Non-Measuring
Specification
[CLP.CON]
Number of
Edge
ON[ON]/OFF[OFF]
[SFC.NUM]
Reflection
power
ON[ON]/OFF[OFF]*
[REF.POW]
TIMING
Specify timing to measure[MEAS]*/
input mode
Specify timing to exposure[EXPOSE] *1
[TIM.MOD]
Output target
TASK1 [TASK1]*/TASK2 [TASK2]/
[OUTPUT]
TASK3 [TASK3]/TASK4 [TASK4]
0 to 99.9999 mm
Hysteresis
(default value: 0.05% of measuring
[HYS]
range)
*2
TIMER
Off* [OFF]/Off delay [OFF.DLY]/
[TIMER]
On delay [ONDLY]/One shot [1SHOT]
*3
Timer time
0.2 to 5000 ms (default value: 0.2)
[TIME]
Search from Menu Tree
* default value
Pages
p.265
p.267
*1
*1
*1
*1
*1
*1
*
*1
p.165
*1
*1
*1
215