Command
GIO+CNFG "<xxxxxxx>"
GIO+STAT?
GIO+STAT "<xxxxxxx>"
GPIO+TRIG <XXXXXXX>
Examples
Get the status of all the inputs:
(GIO+STAT?)
Result:
(GIO+STAT!"LLLLLLL")
All inputs are low.
Set the status of the general purpose outputs:
(GIO+STAT "HXLHLLL")
Result:
Pins 1 and 4 are set to high; pin 2 has no change; Pins 2, 5, 6, and 7 are set to low.
Get the direction for the individual pins:
(GIO+CNFG?)
Result:
(GIO+CONFG!"IIIIIII")
Set pins 1, 2, and 6 to input and set pins 3, 4,5, and 7 to output:
(GIO+CNFG "II000I0")
Set pins 1 and 2 to output and ignore the rest:
(GIO+CNFG "00XXXXX")
ITP–Test Pattern
Displays a test pattern.
Commands
Command
Description
ITP <index>
Enables or disables test patterns.
Christie TruLife+ Technical Reference–Serial Commands
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Description
Sets the direction for the individual pins to input or outputs.
Returns the status of all inputs. (Read-only)
Gets the state of all inputs or sets the state of all outputs.
This command is only available if video electronics are on.
(Saved value)
Sets the GPIO signal to be used as a camera trigger signal.
Serial API commands
Values
I = Input
O = Output
X = No change
H = High
L = Low
X = No change
N = Normal
T = Trigger
X = No change
Values
0 = Off (Default)