Shu-Shutter; Sin-Select Input - Christie 4K35-RGB Technical Reference

Hide thumbs Also See for 4K35-RGB:
Table of Contents

Advertisement

SHU–Shutter
Opens and closes the shutter.
This command may return an incorrect result if the shutter is manually opened or closed.
Commands
Command
Description
SHU?
Gets the state of the shutter. (Read-only)
SHU <0 | 1>
Opens or closes the shutter.
SHU+INHB?
Gets the state of the shutter Inhibit
command. (Read-only)
Only applies to: Christie Eclipse
SHU+INHB <0 | 1>
Enables or disables opening the shutter
during the projector power on sequence.
If disabled, the shutter must be opened
manually.
Only applies to: Christie Eclipse
Examples
Get the state of the shutter:
(SHU?)
Result:
(SHU!0)
Indicates the shutter is open.
Open the shutter:
(SHU 0)
Close the shutter:
(SHU 1)
SIN–Select Input
Selects the active input.
Commands
Command
Description
SIN?L
Returns a list of available inputs to select based on the
selected port configuration. (Read-only)
Christie TruLife+ Technical Reference–Serial Commands
020-103316-07 Rev. 1 (09-2022)
Copyright
©
2022 Christie Digital Systems USA, Inc. All rights reserved.
If printed, please recycle this document after use.
Serial API commands
Values
0 = Opens the shutter
1 = Closes the shutter (Default)
0 = Enables shutter opening during power
on (Default)
1 = Disables shutter opening and shutter
remains closed when the laser is powered
on
Values
51

Advertisement

Table of Contents
loading

This manual is also suitable for:

Trulife+

Table of Contents